← All insights
MedTech

When Should Medical Device Teams Use AI, and When Not?

UBIQ Events
·
November 20, 2026
When Should Medical Device Teams Use AI, and When Not?

Key takeaway

When to use AI in a medical device and in the work of building one: rule-based where the physics is known, AI where it is not, and a simple test for where large language models help engineers and where they fail.

Short answer: Urs Anliker, Head of Digital Biomarkers at Helbling Technik, an engineering services company, gave medical device teams two rules at the 2nd MedTech Meets AI Conference in October 2026. In the device: "Rule-based, when the physics is known. The result is traceable and verifiable against the specified behavior. AI, when the physics is too complex to model. Then AI detects and classifies patterns in the data." In the development process, a large language model helps when you can describe the task "so that a trained junior knows what to do, and what counts as success". Partly clear tasks need an expert to finish them, and blurry, innovative work stays with people.

Key takeaways

  • In the product, AI is the exception that needs a reason. Use rule-based software wherever the behaviour can be specified and verified, and AI only where the signal is too complex to model. European notified bodies ask manufacturers to justify the same choice.
  • In the process, apply the junior test. If a trained junior could do the task from your description, a large language model can do most of it. If the task is only partly clear, the model produces a starting point and an expert finalises it.
  • Innovation is not a prompt. Where a design departs from the state of the art, the knowledge that matters is not written down anywhere the model can read.
  • An experienced reviewer is part of the tool. Without one, the output looks finished while the basis is wrong. The manufacturer stays responsible for every document, whoever or whatever drafted it.
  • The evidence on who gains most is mixed. Studies of customer support and consulting found the largest gains among less experienced staff. Studies of software engineers point the other way. What they share is that the gain depends on how well the task is defined.

What did we hear on our stage?

Urs Anliker, Head of Digital Biomarkers at Helbling Technik, gave a sponsored keynote on the first day of the 2nd MedTech Meets AI Conference. His employer is an engineering services company that develops devices for clients and has no products of its own, so his view is that of a team that builds for others. He used one project to make both of his points: a low-cost optical coherence tomography (OCT) device that patients with age-related macular degeneration use at home.

The clinical problem is timing. Around 196 million people were living with the disease in 2020, a figure projected to reach 288 million by 2040 (Wong et al., 2014), and the wet form is treated with repeated injections into the eye. He described what happens when the next injection is scheduled without knowing how the retina is doing: "Too late: irreversible vision loss. Too early: burden for the patient and inefficient use of the clinic capacity." A device at home that measures the retina between visits can tell the clinic when the patient needs to come in.

To make such a device affordable, his team accepted a worse signal and repaired it in software: "Expensive hardware components have been replaced with cheaper ones. Resulting signal quality reduction has been compensated with sophisticated algorithms." The interesting part is which algorithms. He put the question and answered it himself:

"When do we use rule-based signal processing, and when AI? Rule-based, when the physics is known. The result is traceable and verifiable against the specified behavior. AI, when the physics is too complex to model. Then AI detects and classifies patterns in the data."

In his presentation, the device detected a change in retinal thickness of 25 micrometres with 95% sensitivity and specificity, tested on 218 exams from 52 eyes. He was careful about what that proves: "Performance (on a limited population) similar to healthcare professional".

The second half of the talk turned from the product to the people who build it, and he drew a line between the two: "In the device, it is typically not an LLM. In development, it is typically an LLM." Good results with a large language model, he said, need three things together: AI know-how, domain knowledge and expertise. He showed what happens when one is missing. Ask a model to "Write me the requirements for an insulin pump" and you get "a generic list, with no link to the intended use, the risks or the architecture. People then stop using the LLM." Give it the context but no experienced reviewer and something worse happens: "The output gets polished while the basis stays wrong."

His practical test for any task was this:

"Can you describe the task so that a trained junior knows what to do, and what counts as success? Clear tasks: the LLM is a lever, with up to 100% efficiency gain. Example: unit tests for a specified function. Partly clear tasks: the LLM builds the starting point, and the expert finalizes it. Blurry tasks stay a human task. That is where innovation takes place, where the design deviates from the state of the art. This knowledge cannot be given as context. So you fail with an LLM in two ways. You give it a blurry task. Or you give it a partly clear task without an expert who finalizes it."

He closed with a message for the people who set budgets: "The junior uses the LLM and reaches results, but without full understanding. That limits the gain. The medium performer gains little. The expert gains the most. For management: AI amplifies expertise. Invest in expertise, because expertise provides the context."

When should the device itself use AI?

The rule from the stage, known physics first and AI only for what cannot be modelled, matches what European notified bodies now ask in an audit. Their joint questionnaire on AI in medical devices (Team-NB and IG-NB, version 1, November 2024) asks manufacturers to show that they considered alternatives to AI and to explain why a simpler, more interpretable model was not chosen. The international good machine learning practice principles, finalised by the IMDRF in January 2025, say the same from the other side: the choice and design of a model should be tailored to the data available and to the intended use. A team that can point to a written rule for where AI sits in its architecture, and where it does not, has already answered that question.

The split also keeps the verification burden small. A rule-based component can be tested against its specification like any other software. A learned component needs representative data, a locked test set and a plan for what happens when the model changes. Keeping the learned part as narrow as the problem allows means less of the device depends on evidence that is expensive to produce.

Home OCT is a good example of where AI earns its place. The first such system reached the US market in May 2024, when the FDA granted a De Novo authorisation to Notal Vision's Scanly, in which a cloud algorithm measures fluid in the retina from scans that patients take themselves. In the pivotal study of 180 patients, its findings agreed with in-office OCT in about 86% of cases, both for eyes with fluid and for eyes without (company announcement of the study published in Ophthalmology Science, July 2025). Finding fluid in a noisy image is a pattern that nobody can write down as an equation, which is the case the rule reserves for AI.

Where do large language models help device engineers, and where do they fail?

The claim that small steps work and whole systems fail has recent evidence behind it. In a benchmark that the speaker cited, Babiuch and Smutný (Future Internet, February 2026) gave 27 language models eight programming tasks for a common microcontroller, with a single prompt and no examples, and had two experts score the results. On the two simplest tasks, reading a sensor, 19 and 23 of the 27 models produced code that compiled at the first attempt. On the hardest, a complete chain from the sensor through a database to a dashboard, only three models met every requirement in one pass. The most frequent error was code that called software libraries that do not exist. The models were good at the step and poor at the system, which is why he advised that "the expert guides the tool step by step".

Surveys of working developers describe the same experience. In the Stack Overflow Developer Survey 2025, 84% of respondents used or planned to use AI tools, yet only about 3% said they highly trust the accuracy of the output, and two thirds named answers that are nearly right as their main frustration. A nearly right unit test is quickly fixed. A nearly right risk analysis is a different matter, and that difference is what the junior test captures.

There is also a warning about self-assessment. In a randomised trial by the research group METR (July 2025), 16 experienced open-source developers took 19% longer to complete real tasks in their own code when they were allowed AI tools, while believing they had been about 20% faster. A follow-up in February 2026 with more developers pointed to a modest speed-up, but the authors called the new data unreliable because many participants no longer wanted to work without AI. For a device team, the lesson is to measure where the tools help and not to rely on how productive they feel.

Who gains most from AI: juniors or experts?

Here the published evidence does not fully support the view from the stage, and readers should know both sides. The largest field study so far, of 5,172 customer support agents (Brynjolfsson, Li and Raymond, Quarterly Journal of Economics, 2025), found that an AI assistant raised the number of issues resolved per hour by 15% on average, with the biggest improvement among the least experienced agents and almost none among the most experienced. A 2023 experiment with 758 management consultants (Dell'Acqua et al.) found the same pattern: below-average performers improved by 43% and above-average performers by 17%.

Software engineering studies lean the other way. In a randomised trial at Google with 96 engineers (Paradis et al., ICSE 2025), AI assistance cut the time for a complex task by about 21%, and the engineers who spend more hours a day writing code gained more.

The two findings fit together once the kind of task is taken into account. In customer support, the assistant passes on what the best agents already know, and anyone can see whether the customer's problem was solved. In device development, the output has to be judged by someone who can tell a sound requirement from a plausible one. The consultant study measured this directly: on a task chosen to lie outside what the model could do well, consultants who used AI were 19 percentage points less likely to reach the correct answer than those who worked without it. A junior with a language model reaches a result faster, but in a regulated product a result that nobody on the team can vouch for is not yet worth anything.

What do regulators and notified bodies expect when AI tools are used in development?

No regulator has published rules written specifically for language models in device development, so the existing ones apply. Under ISO 13485, clause 4.1.6, software used in the quality management system must be validated before first use, with an effort proportionate to the risk of that use. Since 2 February 2026 the same standard is part of US law through the FDA's Quality Management System Regulation, and the FDA's guidance on computer software assurance, reissued in February 2026, takes the same risk-based line.

In practice that leads to the reviewer the speaker insisted on. The Johner Institute, a regulatory consultancy, argued in October 2025 that a language model used in a quality process is a computerised system under clause 4.1.6, that validation may be unnecessary where a qualified person fully verifies every output, and that the real danger is a reviewer who stops checking because the text reads well. Notified bodies say the same in public. At a regulatory conference in May 2026, a representative of TÜV SÜD put it in one sentence: "Decisions always have to be made by humans." At the same event a speaker from the French notified body GMED reminded manufacturers that they remain responsible for the accuracy of their technical documentation, including any errors an AI tool introduces (RAPS, trade press, May 2026).

Many companies are not there yet. In a Deloitte survey of 100 medtech leaders published in July 2026 (consultancy research), about one in three said that AI outputs are used informally in their organisation, without updated procedures or validation.

For AI inside the product, the main dates have moved. After the EU's Digital Omnibus entered into force in July 2026, the AI Act's obligations for high-risk AI in medical devices apply from 2 August 2028 (White & Case, law firm summary). In the US, the FDA's guidance on AI-enabled device software, published as a draft in January 2025, is on the agency's list for finalisation in fiscal year 2027.

What does this mean for medical device teams?

The two rules can be turned into working practice without new tools. For the product, write down in the architecture where the behaviour is specified and verified in the classical way and where a learned model is used, with the reason for each learned component. That page answers the notified body's question about simpler alternatives before it is asked.

For the process, sort the work before choosing the tool. Unit tests for a specified function, a first review of a document against a checklist or a summary of a standard are clear tasks, and a language model will do most of the work. A first draft of a requirements specification or a risk analysis is partly clear: the model can produce a starting point only if it is given the intended use, the risks and the architecture, and only if an expert then finishes it. The parts of the design that are new stay with the engineers. The speaker's own example was modest and easy to copy. Before the conference he gave a model "a precise review task for this deck: audience view, consistency, clarity, tone", and then, in his words, "I reviewed the deck myself."

Two decisions belong to management. One is to record which AI tools are used in which quality processes and who verifies the output, because an informal habit is hard to defend in an audit. The other is where to invest. His advice was that context matters more than the choice of model: "Models change every 3 to 6 months. The context stays." The intended use, the risk file and the architecture are the context, and they exist only where experienced people have written them down.

What to watch in 2027

Three developments will shape this topic next year. The FDA plans to finalise its guidance on AI-enabled device software and on predetermined change control plans during fiscal year 2027. In the EU, the European Parliament is expected to vote on the revision of the MDR and IVDR in the first quarter of 2027, with adoption targeted for the middle of the year (Emergo by UL, consultancy summary), while the current MDR transition period for class III and class IIb implantable devices ends on 31 December 2027. And manufacturers preparing for the AI Act can start work with the quality management standard EN 18286, published in July 2026, well before the obligations for devices begin in August 2028.

The 2nd MedTech Meets AI Conference, organised by UBIQ Events, took place in Barcelona on 14 and 15 October 2026. Dates for the next edition will be announced on the conference website.

Sources

  1. Anliker, U. (2026). AI in the Product, AI in the Process: Lessons from a Retinal-Monitoring Case Study. Sponsored keynote at the 2nd MedTech Meets AI Conference, UBIQ Events, Barcelona, 14 October 2026.
  2. Wong, W.L. et al. (2014). Global prevalence of age-related macular degeneration and disease burden projection for 2020 and 2040. The Lancet Global Health. ophth.wisc.edu (accessed 19 November 2026)
  3. Team-NB and IG-NB. (2024). Questionnaire: Artificial Intelligence in Medical Devices, version 1, November 2024. team-nb.org (accessed 19 November 2026)
  4. IMDRF. (2025). Good machine learning practice for medical device development: guiding principles, January 2025. imdrf.org (accessed 19 November 2026)
  5. Notal Vision. (2025). Pivotal data on Scanly home OCT, 9 July 2025 (company announcement). notalvision.com (accessed 19 November 2026)
  6. Babiuch, M. and Smutný, P. (2026). Benchmarking Large Language Models for Embedded Systems Programming in Microcontroller-Driven IoT Applications. Future Internet, 18(2), 94. mdpi.com (accessed 19 November 2026)
  7. Stack Overflow. (2025). Developer Survey 2025: AI. survey.stackoverflow.co (accessed 19 November 2026)
  8. METR. (2025). Measuring the impact of early-2025 AI on experienced open-source developer productivity, July 2025. arxiv.org; update, 24 February 2026. metr.org (accessed 19 November 2026)
  9. Brynjolfsson, E., Li, D. and Raymond, L. (2025). Generative AI at Work. Quarterly Journal of Economics, 140(2). econpapers.repec.org (accessed 19 November 2026)
  10. Dell'Acqua, F. et al. (2023). Navigating the Jagged Technological Frontier, working paper. mitsloan.mit.edu (accessed 19 November 2026)
  11. Paradis, E. et al. (2025). How much does AI impact development speed? An enterprise-based randomized controlled trial. ICSE 2025. conf.researchr.org (accessed 19 November 2026)
  12. FDA. (2026). Quality Management System Regulation, effective 2 February 2026. fda.gov (accessed 19 November 2026)
  13. FDA. (2026). Computer Software Assurance for Production and Quality Management System Software, February 2026. fda.gov (accessed 19 November 2026)
  14. FDA. (2026). CDRH proposed guidances for fiscal year 2027, October 2026. fda.gov (accessed 19 November 2026)
  15. Johner Institute. (2025). Validating ChatGPT, 29 October 2025 (consultancy). johner-institute.com (accessed 19 November 2026)
  16. RAPS Regulatory Focus. (2026). Euro Convergence: experts share insights on AI for submissions and conformity assessments, 15 May 2026 (trade press). raps.org (accessed 19 November 2026)
  17. Deloitte. (2026). MedTech agentic AI in enterprise workflows, 30 July 2026, survey of 100 leaders (consultancy). deloitte.com (accessed 19 November 2026)
  18. White & Case. (2026). EU AI Omnibus enters into force, amending the AI Act, July 2026 (law firm). whitecase.com (accessed 19 November 2026)
  19. Emergo by UL. (2026). Europe targets revised MDR and IVDR adoption in 2027 (consultancy). emergobyul.com (accessed 19 November 2026)

Frequently asked questions

When should a medical device use AI instead of rule-based software?

Use rule-based software wherever the behaviour can be specified, because the result is traceable and can be verified against the specification. Use AI where the physics or the signal is too complex to model and the task is to detect or classify patterns in data. Notified bodies ask manufacturers to justify why a simpler, more interpretable approach was not used.

Can large language models be used in medical device development?

Yes. No regulation forbids it, but the existing rules apply. Software used in the quality system must be validated in proportion to its risk under ISO 13485, clause 4.1.6, and the manufacturer stays responsible for every requirement, test and document. In practice this means a qualified person verifies the output.

Which development tasks are suitable for a large language model?

Tasks that you could describe clearly enough for a trained junior, with a definition of success, such as unit tests for a specified function or a first review of a document. Partly clear tasks, such as a draft requirements specification, need full context and an expert who finalises the result. Innovative work that departs from the state of the art stays a human task.

Do junior or senior engineers benefit more from AI tools?

The evidence is mixed. Large studies of customer support agents and consultants found that less experienced staff gained most. A randomised trial at Google found that engineers who code more gained more. In regulated development the output must be verified, so the gain depends on having someone who can judge it.

Does AI make experienced developers faster?

Not always. In a 2025 randomised trial, 16 experienced open-source developers were 19% slower with AI tools on their own code while believing they were faster. A 2026 follow-up suggested a modest speed-up but called its own data unreliable. Measure the effect on your own tasks.

When does the EU AI Act apply to AI in medical devices?

After the Digital Omnibus entered into force in July 2026, the obligations for high-risk AI in products covered by sector legislation, which includes medical devices, apply from 2 August 2028.

Where can I discuss AI in medical devices with peers?

The MedTech Meets AI Conference, organised by UBIQ Events, brings together R&D, quality, regulatory and digital leaders from medical device companies across Europe.

Join the discussion in person

MedTech Meets AI

Visit the conference